ACT20M-CI-2CO-S   Item No. 1175990000

Signal duplicator/isolator, Input : 0(4)-20 mA, Output : 2 x 0(4) - 20 mA

Please note that any possible discounts or additional costs are not yet applied here. The definitive payment amounts will be shown in the cart.

ACT20M-CI-2CO-S ACT20M-CI-2CO-S ACT20M-CI-2CO-S ACT20M-CI-2CO-S ACT20M-CI-2CO-S

Properties

Version Signal duplicator/isolator, Input : 0(4)-20 mA, Output : 2 x 0(4) - 20 mA  
Order No. 1175990000  
Type ACT20M-CI-2CO-S  
GTIN (EAN) 4032248969982  
Qty. 1 ST  
Depth 114.3 mm  
Depth (inches) 4.499991 inch  
Height 112.5 mm  
Height (inches) 4.429125 inch  
Net weight 83.6 g  
Width 6.1 mm  
Width (inches) 0.240157 inch  
Storage temperature -40 °C...85 °C  
Operating temperature -25 °C...70 °C  
Humidity 95 %, no condensation  
MTBF 219 Years  
REACH SVHC Lead 7439-92-1  
Input 0(4)-20 mA  
Input current 0...20 mA  
4…20mA  
Input resistance, current 70 Ω  
Number of inputs 1  
Sensor Current source  
Sensor with own supply  
4-wire sensor  
Voltage drop, current input < 1.5 V  
Cut-off frequency (-3 dB) 100 Hz  
Load impedance current @ max 23mA  
load impedance voltage ≥ 10 kΩ  
Number of outputs 2  
Output 2 x 0(4) - 20 mA  
Output current 0...20 mA  
4...20 mA  
Accuracy < 0.05 % of measuring range  
Configuration none  
Galvanic isolation 3-way isolator  
Power consumption, max. 0.75 W  
Power consumption, typ. 0.53 W  
Rail TS 35  
Step response time ≤ 7 ms  
Temperature coefficient ≤ 0.01 % / °C  
Type of connection Screw connection  
Voltage supply 24 V DC ± 30 %  
EMC standards IEC 61326-1  
NE 21  
Galvanic isolation 3-way isolator  
Insulation voltage 2.5 kVeff /1 min.  
Pollution severity 2  
Rated voltage 300 Veff  
Surge voltage category II  
Marking II 3 G Ex nA IIC T4 Gc  
Product information The non-adjustable DC isolating amplifier ACT20M-CI-CO-S isolates analogue standard current signals. An analogue input current signal is linearly converted to an analogue output current signal and is galvanically isolated. The power supply is galvanically isolated from the input and output (3-way isolation) by means of direct wiring or the Weidmüller rail bus.

The non-adjustable DC isolation amplifier ACT20M CI-2CO-S offers the same functionality, but has 2 galvanically isolated outputs (4-way isolation).  
Approval/Certificate/Document of Conformity [DNV-GL certificate](http://download.weidmueller.com/asset/download/file/86299)  
[FM certificate](http://download.weidmueller.com/asset/download/file/102445)  
[IECEXx certificate](http://download.weidmueller.com/asset/download/file/102446)  
[ATEX certificate](http://download.weidmueller.com/asset/download/file/102447)  
[Declaration of Conformity](http://download.weidmueller.com/asset/download/file/35386)  
Brochure/Catalogue [CAT 4.1 ELECTR 16/17 EN](http://download.weidmueller.com/asset/download/file/35322)  
Engineering Data [STEP](http://download.weidmueller.com/asset/download/file/52202)  
Engineering Data [EPLAN, WSCAD, Zuken E3.S](LINK/CAE_EN.html)  
CADENAS eCATALOG [Cax data](https://weidmueller-embedded.partcommunity.com?catalog=weidmueller_qs&part=1175990000)  
User Documentation [Instruction sheet](http://download.weidmueller.com/asset/download/file/35877)  
ETIM 6.0 EC002653  
ETIM 7.0 EC002653  
eClass 9.0 27-21-01-20  
eClass 9.1 27-21-01-20  
eClass 10.0 27-21-01-20  
eClass 11.0 27210120  
Long specification

Standard signal splitter
1-channel signal splitter in 6.1 mm width with external power supply,
to transmit, isolate and split analogue DC current signals 0/4...20 mA

Add-on housing for TS35 rail mounting
Dimensions: L/W/H 114.3/ 6.1/ 112.5 mm
Screw connection / Nominal cross-section 2.5 mm2
Protection degree: IP 20  


Input                          0/4...20 mA

Output                                              2 x 0/4...20 mA
Load resistance             < 300 Ohm/ Ausgang
Transmission error             < 0,05 % v. E. 
Limit frequency 100 Hz 
Auxiliary power                                     24 VDC +/- 30 %
Power loss approx. 0.8 W
Ambient
temperature range -25 °C...+70 °C

Isolation                                 EN 61010-1, 3-way isolation up to 2.5 kV AC/DC of all circuits against each other
Test voltage                               2.5 kV input against output against auxiliary power
Rated
voltage                                        
  300 V AC/DC at overvoltage category II and pollution degree 2
Approvals cULus, FM Div2, ATEX Zone2, DNV, GL




Type                                                             ACT20M-CI-2CO-S

 
Short specification

Standard signal splitter
1-channel signal splitter in 6.1 mm width with external power supply,
to transmit, isolate and split analogue DC current signals 0/4 to 20 mA

 
Approvals ![CE](/picture/CE.gif) ![CULUS](/picture/CULUS.gif) ![DETNORVER](/picture/DETNORVER.gif) ![DNVGL](/picture/DNVGL.gif) ![EAC](/picture/EAC.gif) ![FMEX](/picture/FMEX.gif) ![IECEXKEM](/picture/IECEXKEM.gif) ![KEMAATEX](/picture/KEMAATEX.gif)  
ROHS Conform  
UL File Number Search [E337701](LINK/UL_search.html)  

Accessories

  • Item No.
    1335140000
  • Item No.
    1282490000
  • Item No.
    1877680000