Ominaisuudet
Version | Photovoltaics, Assembled enclosure, Combiner Box, With fuse holder, Surge protection II, Cable gland, for wall mounting, Switch disconnector, Current monitoring |
Order No. | 8000050566 |
Type | PV 216S0F0C15V0O3T7P015PJP |
GTIN (EAN) | 8430243406857 |
Qty. | 1 items |
Delivery status | This article will no longer be available in the future. |
Depth | 300 mm |
Depth (inches) | 11,811 inch |
Height | 835 mm |
Height (inches) | 32,874 inch |
Width | 635 mm |
Width (inches) | 25 inch |
Net weight | 24 000 g |
Ambient temperature | -20 °C…50 °C |
RoHS Compliance Status | Compliant |
REACH SVHC | Lead 7439-92-1 |
Earthing | Directly at the VPU |
Rated voltage | 1 500 V |
Surge protection DC side |
1500 V type II with remote contact
1500 V type II |
Surge protection WIA RS485 side (string monitoring) | Yes |
Switching capacity | 400 A (DC21B 1500 V) |
Cartridge fuse | 10 x 85 mm |
Connection DC input cable (+) | Screw connection |
Connection DC input cable (-) | Screw connection |
Connection type, DC input cable | Screw connection |
Fuse | 10 mm x 85 mm , 15 A |
Fuse-link standard | gPV (EN 60269-6) |
Number of conduit inlets | 11 |
Number of DC inputs | 16 |
Number of inputs | 16 |
Number of inputs | 16 |
Position of the fuses | positive and negative inputs |
Auxiliary contact connection from the load circuit breaker | At the digital input of the Transclinic xi+ |
Connection auxiliary contact for the surge protection | At the digital input of the Transclinic xi+ |
Connection type, DC output cable | Screw connection |
DC output cable connection | M12 |
Load circuit breaker with auxiliary contact | Yes |
Number of DC outputs | 2 |
Current monitoring | Transclinic 16i+ H |
Monitoring function | Individual inputs |
Temperature monitoring | Transclinic 16i+ H |
Voltage monitoring | Transclinic 16i+ H |
Protection degree | IP65 |
Type of mounting |
Wall mounting
Mounting plate |
Standards |
EN 61439-2:2011
IEC 61439-2 ed 3.0 |
Approval/Certificate/Document of Conformity | [EU Declaration of Conformity Combiner Boxes monitored](https://mdcop.weidmueller.com/mediadelivery/asset/900_216552) |
User Documentation | [User Manual PV DC Combiner Boxes](https://mdcop.weidmueller.com/mediadelivery/asset/900_207163) |
Catalogues | [Catalogues in PDF-format](LINK/Catalog.html) |
ETIM 6.0 | EC002928 |
ETIM 7.0 | EC002928 |
ETIM 8.0 | EC003857 |
ETIM 9.0 | EC003857 |
ETIM 10.0 | EC003857 |
ECLASS 9.0 | 22-57-92-03 |
ECLASS 9.1 | 22-57-02-90 |
ECLASS 10.0 | 22-57-02-90 |
ECLASS 11.0 | 22-57-02-92 |
ECLASS 12.0 | 22-57-02-92 |
ECLASS 13.0 | 22-57-02-92 |
ECLASS 14.0 | 22-57-02-92 |
ECLASS 15.0 | 22-57-02-92 |
ROHS | Conform |