WGK 95 BK BX   Item No. 1250680000

OMNIMATE Power - series WGK, Feed-through terminal, Rated cross-section: 95 mm², Screw connection, Wemid (PA), black, Direct mounting, Feed-through (bushing)

Please note that any possible discounts or additional costs are not yet applied here. The definitive payment amounts will be shown in the cart.

WGK 95 BK BX WGK 95 BK BX WGK 95 BK BX WGK 95 BK BX WGK 95 BK BX WGK 95 BK BX WGK 95 BK BX

Properties

Type WGK 95 BK BX  
Order No. 1250680000  
Version OMNIMATE Power - series WGK, Feed-through terminal, Rated cross-section: 95 mm², Screw connection, Wemid (PA), black, Direct mounting, Feed-through (bushing)  
GTIN (EAN) 4050118041866  
Qty. 10 ST  
Product data IEC: 1000 V / 232 A / 35 - 95 mm²
UL: 600 V / 255 A / AWG 4 - kcmil 250  
Packaging Box  
Length 95 mm  
Length (inches) 3.74015 inch  
Width 25 mm  
Width (inches) 0.98425 inch  
Height 74 mm  
Height (inches) 2.91338 inch  
Height of lowest version 74 mm  
Net weight 246.1 g  
Product family OMNIMATE Power - series WGK  
Wire connection method Screw connection  
Conductor outlet direction 180°  
Fitted by customer No  
Tightening torque, min. 15 Nm  
Tightening torque, max. 20 Nm  
Clamping screw M8/Hexagon  
Stripping length 27 mm  
Touch-safe protection acc. to DIN VDE 0470 IP 20  
Insulating material Wemid (PA)  
Colour black  
Colour chart (similar) RAL 9011  
UL 94 flammability rating V-0  
Contact material E-Cu  
Contact surface tinned  
Storage temperature, min. -25 °C  
Storage temperature, max. 55 °C  
Max. relative humidity during storage 80 %  
Operating temperature, min. -50 °C  
Operating temperature, max. 120 °C  
Temperature range, installation, min. -25 °C  
Temperature range, installation, max. 120 °C  
Clamping range, min. 35 mm²  
Clamping range, max. 95 mm²  
Wire connection cross section AWG, min. AWG 4  
Wire connection cross section AWG, max. kcmil 250  
Solid, min. H05(07) V-U 35 mm²  
Solid, max. H05(07) V-U 95 mm²  
Stranded, min. H07V-R 35 mm²  
Stranded, max. H07V-R 95 mm²  
Flexible, min. H05(07) V-K 35 mm²  
Flexible, max. H05(07) V-K 95 mm²  
w. wire end ferrule, DIN 46228 pt 1, min. 35 mm²  
w. wire end ferrule, DIN 46228 pt 1, max. 95 mm²  
Max. clamping range 95 mm²  
tested acc. to standard IEC 60664-1  
IEC 61984  
Rated current, min. number of poles (Tu=20°C) 232 A  
Rated current, max. number of poles (Tu=20°C) 232 A  
Rated voltage for surge voltage class / pollution degree III/3 1000 V  
Rated impulse voltage for surge voltage class/ contamination degree III/3 8 kV  
Rated voltage (Use group B / CSA) 600 V  
Rated voltage (Use group C / CSA) 600 V  
Rated current (Use group B / CSA) 255 A  
Rated current (Use group C / CSA) 255 A  
Wire cross-section, AWG, min. AWG 4  
Wire cross-section, AWG, max. kcmil 250  
Institute (cURus) CURUS  
Certificate No. (cURus) E60693  
Rated voltage (Use group B / UL 1059) 600 V  
Rated voltage (Use group C / UL 1059) 600 V  
Rated current (Use group B / UL 1059) 255 A  
Rated current (Use group C / UL 1059) 255 A  
Wire cross-section, AWG, min. AWG 4  
Wire cross-section, AWG, max. kcmil 250  
Reference to approval values Specifications are maximum values, details - see approval certificate.  
Packaging Box  
VPE length 100 mm  
VPE width 120 mm  
VPE height 270 mm  
Approval/Certificate/Document of Conformity [Declaration of the Manufacturer](http://download.weidmueller.com/asset/download/file/39474)  
Brochure/Catalogue [FL DRIVES EN](http://download.weidmueller.com/asset/download/file/40061)  
[MB DEVICE MANUF. EN](http://download.weidmueller.com/asset/download/file/38257)  
[FL DRIVES DE](http://download.weidmueller.com/asset/download/file/40062)  
[CAT 2 PORTFOLIOGUIDE EN](http://download.weidmueller.com/asset/download/file/39473)  
[FL_BASE_STATION_EN](http://download.weidmueller.com/asset/download/file/38194)  
[FL ELEVATOR EN](http://download.weidmueller.com/asset/download/file/38203)  
[FL POWER SUPPLY EN](http://download.weidmueller.com/asset/download/file/38213)  
[FL 72H SAMPLE SER EN](http://download.weidmueller.com/asset/download/file/38294)  
[PO OMNIMATE EN](http://download.weidmueller.com/asset/download/file/38132)  
Engineering Data [EPLAN, WSCAD](LINK/CAE_EN.html)  
Engineering Data [STEP](http://download.weidmueller.com/asset/download/file/70234)  
CADENAS eCATALOG [Cax data](https://weidmueller-embedded.partcommunity.com?catalog=weidmueller_qs&part=1250680000)  
ETIM 6.0 EC001283  
ETIM 7.0 EC001283  
eClass 9.0 27-14-11-34  
eClass 9.1 27-14-11-34  
eClass 10.0 27-14-11-34  
Approvals ![CURUS](/picture/CURUS.gif) ![EAC](/picture/EAC.gif)  
ROHS Conform  
UL File Number Search [E60693](LINK/UL_search.html)  
Notes
  • Clearance and creepage distances to other components must be devised in accordance with the relevant application standard. This can be achieved in the device by full encapsulation or by the use of additional spacer plates.
  • Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards.
  • Colours: SW = black; GN/YL = green/yellow; GY = grey
  • Additional colours on request
  • WGK: Rated voltage plastic walls: 1–6 mm = 1000 V; metal walls: < 1 mm = 1000 V; metal walls: 1–3.5 mm = 800 V; metal walls: 3.5–5.5 mm = 690 V
  • Wire-end ferrules are mandatory for stranded wires with more than 19 strands.
 

Accessories

  • DEK 5/5 MC NE WS
    always available

    Item No.
    1609801044
  • Item No.
    1937020000
  • Item No.
    1250620000
  • DEK 5/8 MC NE WS
    always available

    Item No.
    1856740000
  • DEK 5/6 MC NE WS
    always available

    Item No.
    1609820000
  • Item No.
    9008850000