BLZ 7.62HP/12/180 SN OR BX

PCB plug-in connector, female plug, 7.62 mm, Number of poles: 12, 180°, Clamping yoke connection, Clamping range, max. : 4 mm², Box

Tuotteen tunnus 1980580000

Approvals

Dopuszczenia
ROHS
UL File Number Search
Certificate No. (cURus)

General ordering data

Wersja
Nr zam.
Typ
GTIN (EAN)
Qty.
Product data
Packaging

Dimensions and weights

Głębokość
Depth (inches)
Wysokość
Height (inches)
Szerokość
Width (inches)
Masa netto

Environmental Product Compliance

Status zgodności z dyrektywą RoHS
REACH SVHC
Product Carbon Footprint

System Parameters

Product family
Type of connection
Wire connection method
Pitch in mm (P)
Pitch in inches (P)
Conductor outlet direction
Number of poles
L1 in mm
L1 in inches
Number of rows
Pin series quantity
Rated cross-section
Touch-safe protection acc. to DIN VDE 57 106
Touch-safe protection acc. to DIN VDE 0470
Protection degree
Volume resistance
Can be coded
Stripping length
Tightening torque, min.
Tightening torque, max.
Clamping screw
Screwdriver blade
Screwdriver blade standard
Plugging cycles
Plugging force/pole, max.
Pulling force/pole, max.

Material data

Insulating material
Barwny
Tabela kolorów (podobny)
Insulating material group
Comparative Tracking Index (CTI)
Opór izolacji
UL 94 flammability rating
Materiał styków
Contact surface
Layer structure of plug contact
Storage temperature, min.
Storage temperature, max.
Operating temperature, min.
Operating temperature, max.
Temperature range, installation, min.
Temperature range, installation, max.

Conductors suitable for connection

Clamping range, min.
Zakres zaciskania, maks.
Wire connection cross section AWG, min.
przekrój przyłączeniowy przewodu AWG, maks.
Solid, min. H05(07) V-U
rigido, max. H05(07) V-U
Flexible, min. H05(07) V-K
Flexible, max. H05(07) V-K
z AEH z kołnierzem DIN 46 228/4, min.
w. plastic collar ferrule, DIN 46228 pt 4, max.
w. wire end ferrule, DIN 46228 pt 1, min.
z końcówką kablową wg DIN 46 228/1, maks.
Plug gauge in accordance with EN 60999 a x b; ø
Clampable conductor
Reference text

Rated data acc. to IEC

tested acc. to standard
Rated current, min. number of poles (Tu=20°C)
Rated current, max. number of poles (Tu=20°C)
Prąd znamionowy, min. liczba biegunów (Tu=40°C)
Rated current, max. number of poles (Tu=40°C)
Rated voltage for surge voltage class / pollution degree II/2
Rated voltage for surge voltage class / pollution degree III/2
Rated voltage for surge voltage class / pollution degree III/3
Rated impulse voltage for surge voltage class/ pollution degree II/2
Rated impulse voltage for surge voltage class/ pollution degree III/2
Rated impulse voltage for surge voltage class/ contamination degree III/3
Short-time withstand current resistance
Odstęp izolacyjny powietrzny, min.
Расстояние утечки, мин.

Rated data acc. to CSA

Institute (CSA)
Certificate No. (CSA)
Rated voltage (Use group B / CSA)
Rated voltage (Use group C / CSA)
Rated voltage (Use group D / CSA)
Rated current (Use group B / CSA)
Rated current (Use group C / CSA)
Jmenovitý proud (aplikační skupina D / CSA)
Wire cross-section, AWG, min.
Wire cross-section, AWG, max.
Odkaz na hodnoty pro schválení

Rated data acc. to UL 1059

Institute (cURus)
Certificate No. (cURus)
Rated voltage (Use group B / UL 1059)
Rated voltage (Use group C / UL 1059)
Rated voltage (Use group D / UL 1059)
Rated current (Use group B / UL 1059)
Rated current (Use group C / UL 1059)
Rated current (Use group D / UL 1059)
Wire cross-section, AWG, min.
Wire cross-section, AWG, max.
Référence aux valeurs approuvées

Packing

Packaging
VPE length
VPE width
VPE height

Type tests

Test: Durability of markings
Test: Misengagement (Non-interchangeability)
Test: Clampable cross section
Test for damage to and accidental loosening of conductors
Pull-out test

Important note

Zgodność IPC
Uwagi

Classifications

ETIM 8.0
ETIM 9.0
ETIM 10.0
ECLASS 14.0
ECLASS 15.0