ACT20X-2HAI-2SAO-P   Item No. 2456150000

EX signal isolating converter, Ex-input: 4 - 20 mA, Safe-output: 4-20mA, 2-channel

Please note that any possible discounts or additional costs are not yet applied here. The definitive payment amounts will be shown in the cart.

ACT20X-2HAI-2SAO-P

Properties

Type ACT20X-2HAI-2SAO-P  
Order No. 2456150000  
Version EX signal isolating converter, Ex-input: 4 - 20 mA, Safe-output: 4-20mA, 2-channel  
GTIN (EAN) 4050118471281  
Qty. 1 ST  
Width 22.5 mm  
Width (inches) 0.885825 inch  
Height 127.3 mm  
Height (inches) 5.011801 inch  
Depth 114.6 mm  
Depth (inches) 4.511802 inch  
Net weight 212 g  
Humidity 0...95 % (no condensation)  
Operating temperature, max. 60 °C  
Operating temperature, min. -20 °C  
Storage temperature, max. 85 °C  
Storage temperature, min. -20 °C  
Operating temperature -20 °C...60 °C  
Storage temperature -20 °C...85 °C  
MTBF 315 Years  
SIL PAPER [SIL certificate](PDF/Cert_Weidmueller_070902_P0002_C006_V2R1.pdf)  
REACH SVHC Lead 7439-92-1  
UL certificate [E337701.pdf](PDF/QUYX.E337701.pdf)  
Input current 4…20mA  
Input frequency 0,5…2,5 kHz @ 3,5…23 mA bi-directional HART® signal  
Output signal in case of wire break < 1 mA  
Residual ripple (current loop) < 7.5 mVeff  
Sensor supply 3.8…26 V DC  
Type intrinsically safe circuit  
active (as current source) or passive (as current sink)  
Voltage drop not powered < 6 V  
Voltage drop powered < 4.5 V  
Load stability ≤ 0.01 % of end value / 100 Ω  
Type active (as current source) or passive (as current sink)  
2-wire supply ≤ 26 V DC  
Output signal limit < 28 mA  
Output current 4...20 mA  
Cut-off frequency (-3 dB) 0.5…2.5 kHz @ 3.5…23 mA bi-directional HART® signal  
Load impedance current ≤ 600 Ω  
Influence of load resistance ≤ 0.01% of span / 100 Ω  
Alarm function Signal limit exceeded  
Line interruption at the input  
No supply voltage  
Device error  
Type Relay, 1 NC (voltage-free)  
Nominal switching voltage ≤ 125 V AC / 110 V DC (safe area)
≤ 32 V AC / 32 V DC (zone 2)  
Continuous current ≤ 0.5 A AC / 0.3 A DC (safe zone)  
≤ 0,5 A AC / 1 A DC (zone 2)  
Power rating ≤ 62.5 VA / 32 W (safe area)
≤ 16 VA / 32 W (Zone 2)  
Configuration With FDT/DTM software  
Voltage supply 19.2…31.2 V DC  
Power consumption ≤ 1.9 W  
Accuracy < 0.1% span  
Temperature coefficient < 0.01% of span/°C (TU)  
Step response time ≤ 5 ms  
Protection degree IP20  
Humidity 0...95 % (no condensation)  
Type of connection PUSH IN  
EMC standards DIN EN 61326  
NE 21  
Insulation voltage 2.6 kV (input / output)  
Rated voltage 300 V  
Voltage U0 Current loop 28 V / externally 10 V  
Current I0 Current loop 93 mA / externally 10 mA  
Power P0 Current loop 0.65 W / externally 0.1 W  
Marking II (1) G [Ex ia Ga] IIC/IIB/IIA  
II (1) D [Ex ia Da] IIIC  
I (M1) [Ex ia Ma] I  
Installation location Device installed in safe area, zone 2  
Demand mode High  
Description of the "safe state" analogue Output ≤ 3.6 mA or output ≥ 21 mA  
Device type A  
Hardware fault tolerance (HFT) 0  
Mean Time To Repair (MTTR) 24 h  
Safe Failure Fraction (SFF) 85 %  
Tproof 5 Years  
Total failure rate for dangerous detected failures (λDD) 127 FIT  
Total failure rate for dangerous undetected failures (λDU) 48 FIT  
Total failure rate for safe detected failures (λSD) 0 FIT  
Total failure rate for safe undetected failures (λSU) 164 FIT  
Safety category SIL 2  
Probability of outage PFH 4.1 x 10-8 h-1  
Average Probability of Failure on Demand (PFDavg) 1.92 x 10-4 (Tproof = 1 year)  
3.67 x 10-4 (Tproof = 2 years)  
8.92 x 10-4 (Tproof = 5 years)  
Type of connection PUSH IN  
Wire connection cross section AWG, min. AWG 26  
Wire connection cross section AWG, max. AWG 14  
Wire cross-section, solid, min. 0.2 mm²  
Wire cross-section, solid, max. 2.5 mm²  
Wire connection cross-section, finely stranded, min. 0.2 mm²  
Wire connection cross section, finely stranded, max. 2.5 mm²  
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. 0.2 mm²  
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. 2.5 mm²  
ATEX certificate [11ATEX0131X.pdf](PDF/216740400-11ATEX0131X-Iss2-E.pdf)  
IEC Ex certificate [IECEx certification](PDF/216740400-CoC_DEK11.0050X-Iss1.pdf)  
Approval/Certificate/Document of Conformity [Certification SIL](http://download.weidmueller.com/asset/download/file/35863)  
[Certification DNV GL](http://download.weidmueller.com/asset/download/file/42626)  
[Certification ATEX](http://download.weidmueller.com/asset/download/file/97028)  
[Certification IECEx](http://download.weidmueller.com/asset/download/file/97151)  
[Certification UL](http://download.weidmueller.com/asset/download/file/103193)  
[Declaration of Conformity](http://download.weidmueller.com/asset/download/file/35395)  
Engineering Data [STEP](http://download.weidmueller.com/asset/download/file/66116)  
CADENAS eCATALOG [Cax data](https://weidmueller-embedded.partcommunity.com?catalog=weidmueller_qs&part=2456150000)  
Software [WI-Manager, DTM-Library for online installation V.1.2.0](http://download.weidmueller.com/asset/download/file/35364)  
User Documentation [SIL certificate](http://download.weidmueller.com/asset/download/file/40040)  
[Instruction sheet](http://download.weidmueller.com/asset/download/file/80487)  
[Handbuch ACT20X- Serie, deutsch](http://download.weidmueller.com/asset/download/file/102720)  
[Manual ACT20X- series, english](http://download.weidmueller.com/asset/download/file/102722)  
ETIM 6.0 EC002653  
ETIM 7.0 EC002653  
eClass 9.0 27-21-01-20  
eClass 9.1 27-21-01-90  
eClass 10.0 27-21-01-20  
Approvals ![CULUS](/picture/CULUS.gif) ![DNVGL](/picture/DNVGL.gif) ![EAC](/picture/EAC.gif)  
ROHS Conform  
UL File Number Search [E337701](LINK/UL_search.html)  

Accessories

  • Item No.
    8978580000
  • Item No.
    1082540000
  • Item No.
    1912130000