ACT20C-CML-10-AO-RC-S   Item No. 2044840000

Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay

Please note that any possible discounts or additional costs are not yet applied here. The definitive payment amounts will be shown in the cart.

ACT20C-CML-10-AO-RC-S ACT20C-CML-10-AO-RC-S ACT20C-CML-10-AO-RC-S ACT20C-CML-10-AO-RC-S ACT20C-CML-10-AO-RC-S

Properties

Type ACT20C-CML-10-AO-RC-S  
Order No. 2044840000  
Version Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay  
GTIN (EAN) 4050118409826  
Qty. 1 ST  
Width 17.5 mm  
Width (inches) 0.688975 inch  
Height 117.2 mm  
Height (inches) 4.614164 inch  
Depth 113.6 mm  
Depth (inches) 4.472432 inch  
Net weight 134 g  
Humidity 5...95 %, no condensation  
Storage temperature, max. 85 °C  
Storage temperature, min. -40 °C  
Ambient temperature -25 °C...+70 °C  
Storage temperature -40 °C...85 °C  
MTTF 130 Years  
REACH SVHC Lead 7439-92-1  
Configuration for thresholds (overcurrent ⁄ undercurrent), delay and hysteresis  
via gateway (ACT20C-GTW-100-MTCP-S)  
With FDT/DTM software  
Input signal Power cable can be connected to the terminals  
Input measurement range 0…1/5/10 A AC (RMS) or DC  
Input frequency AC: 15…400 Hz (true root mean square)  
AC: 50 Hz (arithmetic average)  
Accuracy ≤ ±0.3 % @ 1 A ⁄ 5 A  
≤ ±0.6 % @ 10 A  
Configuration for thresholds (overcurrent ⁄ undercurrent), delay and hysteresis  
via gateway (ACT20C-GTW-100-MTCP-S)  
With FDT/DTM software  
Galvanic isolation 4-way isolator;  
between input ⁄ output ⁄ supply ⁄ relay  
Power consumption, max. 2.2 W  
Rail TS 35  
Step response time ≤ 300 ms (RMS)  
≤ 60 ms (AA)  
Temperature coefficient ≤ ±100 ppm⁄K @ -25…+55 °C  
≤ ±200 ppm/K @ +55…+70 °C  
Voltage supply 24 V DC ± 30 %  
EMC standards IEC 61326-1  
IEC 61010-2-201  
Galvanic isolation 4-way isolator;  
between input ⁄ output ⁄ supply ⁄ relay  
Impulse withstand voltage 6 kV (1.2/50 µs)  
Pollution severity 2  
Rated voltage 300 V ACrms  
Surge voltage category III  
Load resistance current ≤ 600 Ω  
Load resistance voltage ≥ 10 kΩ  
Output current -20…+20 mA  
Output voltage 2…10 V  
-5…+5 V  
Type (analogue output) Voltage and current output (configurable)  
Type Relay, 1 CO contact  
Process alarms (4x) with hysteresis  
with alarm delay (configurable) 0…180 s  
Max. switching voltage, DC 24 V  
Max. switching voltage, AC 250 V  
Rated switching current 2 A  
Type of connection Screw connection  
Tightening torque, min. 0.5 Nm  
Tightening torque, max. 3.5 Lb In  
Clamping range, rated connection 1.5 mm²  
Clamping range, min. 0.5 mm²  
Clamping range, max. 2.5 mm²  
Wire connection cross section AWG, min. AWG 30  
Wire connection cross section AWG, max. AWG 14  
Wire cross-section, solid, min. 0.5 mm²  
Wire cross-section, solid, max. 2.5 mm²  
Certificate no. (cULus) E141197  
Approval/Certificate/Document of Conformity [DNV GL certification](http://download.weidmueller.com/asset/download/file/52740)  
[Declaration of Conformity](http://download.weidmueller.com/asset/download/file/35446)  
Engineering Data [STEP](http://download.weidmueller.com/asset/download/file/89471)  
CADENAS eCATALOG [Cax data](https://weidmueller-embedded.partcommunity.com?catalog=weidmueller_qs&part=2044840000)  
Software [WI-Manager, DTM-Library for online installation V.1.2.0](http://download.weidmueller.com/asset/download/file/35364)  
User Documentation [Instruction sheet](http://download.weidmueller.com/asset/download/file/38123)  
[Manual](http://download.weidmueller.com/asset/download/file/39939)  
ETIM 6.0 EC002475  
ETIM 7.0 EC002475  
eClass 9.0 27-21-01-23  
eClass 9.1 27-21-01-23  
eClass 10.0 27-21-01-23  
Approvals ![CULUS](/picture/CULUS.gif) ![DNVGL](/picture/DNVGL.gif) ![EAC](/picture/EAC.gif)  
ROHS Conform  
UL File Number Search [E141197](LINK/UL_search.html)  

Accessories

  • Item No.
    1335140000
  • Item No.
    1082520000
  • Item No.
    1912130000
  • Item No.
    1193170000
  • Item No.
    1510340000
  • Item No.
    1193160000