ACT20M-CI-CO-OLP-S   Item No. 1176040000

Signal converter/insulator, Output current loop powered, 1-channel, Input : 4-20 mA, Output : 4-20 mA

Please note that any possible discounts or additional costs are not yet applied here. The definitive payment amounts will be shown in the cart.

ACT20M-CI-CO-OLP-S ACT20M-CI-CO-OLP-S ACT20M-CI-CO-OLP-S ACT20M-CI-CO-OLP-S ACT20M-CI-CO-OLP-S

Properties

Type ACT20M-CI-CO-OLP-S  
Order No. 1176040000  
Version Signal converter/insulator, Output current loop powered, 1-channel, Input : 4-20 mA, Output : 4-20 mA  
GTIN (EAN) 4032248970155  
Qty. 1 ST  
Width 6.1 mm  
Width (inches) 0.240157 inch  
Height 112.5 mm  
Height (inches) 4.429125 inch  
Depth 114.3 mm  
Depth (inches) 4.499991 inch  
Net weight 80 g  
Humidity 40 °C / 93 % rel. humidity, no condensation  
Operating temperature, max. 70 °C  
Operating temperature, min. -25 °C  
Storage temperature, max. 85 °C  
Storage temperature, min. -40 °C  
Operating temperature -25 °C...70 °C  
Ambient temperature -25 °C...+70 °C  
Storage temperature -40 °C...85 °C  
REACH SVHC Lead 7439-92-1  
UL certificate [E337701.pdf](PDF/QUYX.E337701.pdf)  
Number of inputs 1  
Sensor 2-wire transmitter (without own power supply)  
Sensor supply 6…35 V (@ 20 mA)  
Input current 4…20mA  
Voltage drop, current input Typical 2.5 V  
Number of outputs 1  
Output current 4...20 mA  
Cut-off frequency (-3 dB) 100 Hz  
load impedance current @ max 23mA  
Supply voltage 6…35 V  
Accuracy < 0.05 % of measuring range  
Configuration none  
Galvanic isolation 2-way isolator  
Power consumption, max. 0.5 W  
Rail TS 35  
Step response time ≤ 5 ms  
Temperature coefficient ≤±0.02 µA x (Δ °C x V supply) @ Tamb > 25 °C  
Voltage supply Output loop powered  
EMC standards IEC 61326-1  
NE 21  
Galvanic isolation 2-way isolator  
Insulation voltage 2.5 kVeff /1 min.  
Pollution severity 2  
Rated voltage 300 Veff  
Standards IEC 61010-1  
Surge voltage category II  
Marking II 3 G Ex nA IIC T4 Gc  
Type of connection Screw connection  
Tightening torque, min. 0.4 Nm  
Tightening torque, max. 0.6 Nm  
Clamping range, rated connection 2.5 mm²  
Clamping range, min. 0.5 mm²  
Clamping range, max. 2.5 mm²  
Wire connection cross section AWG, min. AWG 30  
Wire connection cross section AWG, max. AWG 14  
Certificate No. (ATEX) KEMA10ATEX0183X  
Certificate No. (IECEX) IECEXKEM10.0090X  
Product information The passive isolator ACT20M-CI-CO-OLP-S isolates standard analogue current signals. An analogue input current signal is linearly converted into an analogue output current signal and is galvanically isolated. Power is supplied through the output measuring circuit (output loop-powered).  
Descriptive text technical data Power supply optionally over the DIN mounting rail CH20M  
Instructions for accessories DIN mounting rail, see Accessories  
Approval/Certificate/Document of Conformity [DNV-GL certificate](http://download.weidmueller.com/asset/download/file/86299)  
[Declaration of Conformity](http://download.weidmueller.com/asset/download/file/35386)  
Brochure/Catalogue [CAT 4.1 ELECTR 16/17 EN](http://download.weidmueller.com/asset/download/file/35322)  
Engineering Data [EPLAN, WSCAD, Zuken E3.S](LINK/CAE_EN.html)  
Engineering Data [STEP](http://download.weidmueller.com/asset/download/file/52197)  
User Documentation [Instruction sheet](http://download.weidmueller.com/asset/download/file/35875)  
Long specification

Standard signal isolating amplifier
1-channel signal isolating amplifier in 6.1 mm width output-loop powered,
for transmitting and isolating analogue DC current signals 0/4...20 mA.

Add-on housing for TS35 rail mounting
Dimensions: L/W/H 114.3/ 6.1/ 112.5 mm
Screw connection / Nominal cross-section 2.5 mm2
Protection degree: IP 20  


Input                         0/4...20 mA

Output                                             0/4...20 mA
Load resistance             < 600 Ohm
Transmission error             < 0,1 % v. E. 
Limit frequency 100 Hz
Auxiliary power                                     0/4...20 mA output current loop
Power loss approx. 0.9 W
Ambient
temperature range -25 °C...+70 °C

Isolation                                EN 61010-1, 2-way isolation up to 2.5 kV AC/DC
Test voltage                               2.5 kV input against output against auxiliary power
Rated
voltage                                        
  300 V AC/DC at overvoltage category II and pollution degree 2
Approvals cULus, FM Div2, ATEX Zone2, DNV, GL




Type                                                             ACT20M-CI-CO-OLP-S

 
Short specification Standard signal isolating amplifier
1-channel signal isolating amplifier in 6.1 mm width with output current loop feed,
for transmitting and isolating analogue DC current signals from 0/4 to 20 mA.
 
eClass 6.2 27-21-01-20  
eClass 7.1 27-21-01-20  
eClass 8.1 27-21-01-20  
eClass 9.0 27-21-01-20  
eClass 9.1 27-21-01-20  
ETIM 3.0 EC002479  
ETIM 4.0 EC002653  
ETIM 5.0 EC002653  
ETIM 6.0 EC002653  
Approvals ![CULUS](/picture/CULUS.gif) ![DETNORVER](/picture/DETNORVER.gif) ![DNVGL](/picture/DNVGL.gif) ![EAC](/picture/EAC.gif) ![FMEX](/picture/FMEX.gif) ![IECEXKEM](/picture/IECEXKEM.gif) ![KEMAATEX](/picture/KEMAATEX.gif)  
ROHS Conform  
UL File Number Search [E337701](LINK/UL_search.html)  

Accessories

  • Item No.
    1877680000